On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Prediction of thermodynamic parameters in gas chromatography from molecular structure: hydrocarbons
Matevz Pompe1, Joe M Davis, Clint D Samuel
1Faculty of Chemistry and Chemical Technology, University of Ljubljana, Askerceva 5, 1000 Ljubljana, Slovenia. matevz.pompe@uni-lj.si
Abstract:
Theoretical prediction of gas-chromatographic retention times could be used as an additional method for a more accurate identification of organic compounds during GC/MS analysis. Two separate quantitative structure-property relationship models were introduced for the calculation of thermodynamic values (DeltaH degrees, DeltaS degrees) for aliphatic and aromatic hydrocarbons. These values are required for the calculation of retention times in temperature programmed gas chromatography. Seven-descriptor and five-descriptor MLR models were selected for the calculation of DeltaH degrees and DeltaS degrees values, respectively, based on the best cross-validation abilities. The final prediction capabilities of the models were evaluated by a test set procedure. RMS errors calculated from the test set were 207 cal mol(-1) and 0.58 cal mol(-1) K(-1) for DeltaH degrees and DeltaS degrees prediction models, respectively. To evaluate the error of the models represented in the time scale, several chromatograms were simulated using experimental Pro ezGC and theoretically calculated thermodynamic data. Afterward a standard deviation of retention time residuals was calculated. It was found out that, although the standard deviation varies from one chromatographic condition to another, the ratio between the standard deviation and the maximum available separation space for the particular set of organic compounds remains constant and was around 5% of the maximum separation space available at selected chromatographic conditions. Our prediction model was able to accurately differentiate between the retention times of the consecutive compounds in the n-alkanes, 1-alkenes, and 2-alkenes homological series.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II