Influence of the spectral bandwith of the spectrometer on the sensitivity using continuum source AAS
H Becker-Ross1, S Florek, U Heitmann
1Institut für Spektrochemie und angewandte Spektroskopie (ISAS), Laboratorium für spektroskopische Methoden der Umweltanalytik (LSMU), Rudower Chaussee 5, D-12489, Berlin, Germany.
Abstract:
The influence of the spectral bandwidth of the spectrometer on the performance of the spectrometer is of great importance in atomic absorption spectrometry using continuum source (CS-AAS). For a theoretical analysis of the detection of small absorbances two cases have to be taken into account: as long as the limiting noise of the signal is given by the detector noise an increase in spectral bandwidth of the spectrometer implies an improvement in the limit of detection. In contrast, if the noise of the signal is dominated by the photon shot noise the detection limit should become independent of the spectral bandwidth. In this case the spectral bandwidth of the spectrometer should be chosen equal to the bandwidth of the absorption line to avoid spectral interferences. Theoretical calculations are presented for the dependence of the characteristic mass on the spectral bandwidth in case of CS-AAS measurements. The results are compared with experimental measurements for six different elements using continuum source as well as line sources. The investigations were done using a double echelle monochromator (DEMON) which offers a high spectral resolution lambda/Deltalambda of about 140,000.
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...