Cognition is cool: Can hemispheric activation be assessed by tympanic membrane thermometry?
Related Experiment Video
Updated: Aug 25, 2026

Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
Published on: January 5, 2014
Nicolas Cherbuin1, Cobie Brinkman
1Australian National University, School of Psychology, Building 39, Canberra, ACT 0200, Australia. n.cherbuin@anu.edu.au
Abstract:
Hemispheric activation during cognitive tasks using functional magnetic resonance imaging (fMRI) can be difficult to interpret, uncomfortable, and is not widely available. This study investigated whether tympanic membrane thermometry could be used as a broad measure of hemispheric activation. Infrared probes measured ear temperature continuously while subjects performed left or right hemisphere tasks. Temperature decreased in the left ear as activation increased in the left hemisphere during a verbal task, and in the right ear during a visuo-spatial task. When compared to a baseline, ear temperature measurements appeared to reflect relative changes in activation of the left and right hemispheres. Tympanic membrane thermometry therefore may be used as a broad marker of hemispheric activation. Its ability to demonstrate relative involvement of the two hemispheres during cognitive processes makes it especially useful in studies of hemispheric interaction. Its low cost, rapid set-up, and non-invasive nature also make it particularly attractive.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...

