Creating Rapid Oxygen Oscillations in Microbial Single-cell Growth Analysis using a Microfluidic Double-layer Device
Published on: July 18, 2025
Oxygen permeation and microbial ingress through a film-coated and uncoated elastomeric closure in A glass vial: a
Mark Andress1, Henry Dull, Thomas Gurley
1Abbott Laboratories, Ashland, Ohio 44805, USA. mark.andress@abbott.com
Abstract:
This is a comparative study of oxygen permeation and microbial ingress into a drug vial stopper that is an elastomeric pharmaceutical compound versus the same compound coated with a thin Teflon-type film coating. The objective of this study is to determine if the film coating causes any changes in the rate of oxygen permeation or microbial ingress into the vial from the environment. From the data obtained it is concluded that the film did not change either the oxygen or microbial ingress into the vial; therefore the stoppers are essentially equivalent with respect to these parameters.