Porous electrodes supported on ion-exchange membranes as electrochemical detectors for supercritical fluid
Rosanna Toniolo1, Nicola Comisso, Gilberto Schiavon
1Department of Chemical Sciences and Technology, University of Udine, Via Cotonificio 108, I-33100 Udine, Italy.
Abstract:
A conveniently assembled electrochemical cell, exploiting a porous electrode supported on a moist perfluorinated ion-exchange polymer, is proposed for profitable electrochemical detection in supercritical fluid chromatography. It consists of a porous Pt working electrode, contacted by the mobile phase from the chromatographic column, which is chemically deposited onto one side of a Nafion membrane. The rear uncoated side of this membrane, acting as a solid polymer electrolyte, is contacted by an electrolyte solution (1 M NaCl) contained in an internal compartment equipped with a Pt counter electrode and a Ag/AgCl, Cl(-) 1 M reference electrode. Ferrocene, eluted with supercritical carbon dioxide through a Spherisorb column installed in a supercritical fluid chromatographic system, was used as electroactive prototype analyte to test the performance of this detector, which turned out to be quite better than that provided by a conventional on-line UV absorbance detector. The recorded peaks were characterized by both a good reproducibility (4.5%) and a linear dependence of their height and area, which extended over a wide concentration range ( approximately 3 orders of magnitude). Moreover, they were not interfered by possible solvent front, unlike peaks recorded by the UV detector. The detection limit, estimated for a signal-to-noise ratio of 3 (4.2 x 10(-11) mol), was lower by approximately 1 order of magnitude than that found for the UV detector. Finally, the long-term stability of this detector was satisfactory in that only a approximately 6% decrease in the current responses was observed after a rather long period (2 months) of continuous use.
More Related Videos
12:00Evaluating the Electrochemical Properties of Supercapacitors using the Three-Electrode System
Published on: January 7, 2022
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
Related Concept Videos
Potentiometry: Membrane Electrodes
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Ion Exchange
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...