Pirkko Pfäffli1, Mervi Hämeilä, Riitta Riala
1Finnish Institute of Occupational Health, Department of Industrial Hygiene and Toxicology, Topeliuksenkatu 41 a A, FIN-00250 Helsinki, Finland. pirkko.pfaffli@ttl.fi
Abstract:
Methylhexahydrophthalic anhydride (MHHPA) is a hardener for hot-cured epoxy resins employed as insulators in the electric industry. MHHPA has only been measured as an ingredient with other alicyclic anhydrides, albeit there are also large processes which use only MHHPA. We collected MHHPA vapour in a set of devices: Teflon filter, glass spiral, TenaxTA tube connected consecutively together. Elution was performed with a solvent mixture of methyl-tert-butyl ether (70%), acetonitrile (30%), and acetic anhydride (0.5%). By capillary GC-ECD, the regression was linear (0.9994) in the practical low concentration range of 0.04-1 microg ml(-1) being equal to 0.001-0.035 mg m(-3) in 30 l of air. The exposure was measured in two factories manufacturing electric appliances. The assembled objects were first impregnated with a liquid epoxy/hardener mixture, and then the resin hardened at elevated temperature. In condenser manufacturing, the operators' 8 h exposure ranged from 0.068 to 0.118 mg m(-3), and the short-term exposure was during operation at ovens mean 1.90 mg m(-3). The impregnation of coiled resistors and transfer of them to ovens caused the worst exposures, short-term mean 3.846 mg m(-3) and long-term mean 2.191 mg m(-3). During the 'baking', the ovens were closed and evacuated, but when the hot objects were moved out of the ovens, they continued during chilling to emit MHHPA, mean 0.366 mg m(-3). In the adjacent areas, assembling, control rooms, offices, the exposure was still significant, 0.017-0.043 mg m(3), due to leaks from the high exposure areas. Mechanical general ventilation and local exhausts were functioning. Respirators were available for short supervising of the hot equipment.
More Related Videos
17:28Human Pluripotent Stem Cell Based Developmental Toxicity Assays for Chemical Safety Screening and Systems Biology Data Generation
Published on: June 17, 2015
11:38High Content Screening Analysis to Evaluate the Toxicological Effects of Harmful and Potentially Harmful Constituents (HPHC)
Published on: May 10, 2016