Evaluation of sampling locations for two radionuclide air-sampling systems based on the requirements of ANSI/HPS
M Y Ballinger1, J M Barnett, J A Glissmeyer
1Pacific Northwest National Laboratory, PO Box 999 MSIN P7-68, Richland, WA 99352, USA. ballingerm@battelle.org
Abstract:
The Pacific Northwest National Laboratory characterized the performance of sampling locations for two radionuclide air-sampling systems that continuously monitor radioactive air emissions from research and development facilities. The testing was conducted to determine whether sampling system locations would meet the criteria for uniform air velocity and contaminant concentration in the American National Standard Institute standard, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities (ANSI/HPS N13.1-1999). The standard is a revision of the 1969 version that the facilities have been required to meet. Whereas the 1969 standard provided prescriptive criteria for the selection of sampling locations, the 1999 standard is performance-based and requires well-mixed sampling locations that must be demonstrated through performance tests that are specified in the standard. Testing at the Life Sciences Laboratory I was performed on the existing stack at the current sampling location; a scale model was built and used in place of the Radiochemical Processing Laboratory. Although both facilities' sampling sites were compliant with the 1969 standard, only the Radiochemical Processing Laboratory met the criteria of the revised standard. In the future, the use of a computational fluid dynamics computer model may be useful in determining whether a sampling location is likely to test successfully.
Related Concept Videos
Sampling Methods: Overview
In analytical chemistry, the choice of sampling...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Atomic Emission Spectroscopy: Lab
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...