Related Experiment Video
Updated: Aug 25, 2026

Optimized Griess Reaction for UV-Vis and Naked-eye Determination of Anti-malarial Primaquine
Published on: October 11, 2019
Liquid chromatographic determination of amodiaquine in human plasma
Virendra K Dua1, N C Gupta, V P Sharma
1Malaria Research Centre, Field Station, Sector III, BHEL, Hardwar 249403, India. virendradua@hotmail.com
Abstract:
A normal-phase high-performance liquid chromatographic method using dichloromethane- methanol-1M perchloric acid (100:10:0.9, v/v/v) at a flow rate of 1.0 ml min(-1) on a LiChrospher Si column with UV (254 nm) detection has been developed for the determination of amodiaquine and its metabolites desethyl amodiaquine and bisdesethyl amodiaquine in plasma. The limit of quantification was 5 ng ml(-1). Mean within-day and day-to-day coefficients of variation (CV) were 4.10 and 6.27% for amodiaquine, 3.43 and 4.80% for desethyl amodiaquine and 3.53 and 5.23% for bisdesethyl amodiaquine, respectively. Mean extraction recovery of amodiaquine, desethyl amodiaquine and bisdesethyl amodiaquine from plasma were 82.48, 74.50 and 69.65%, respectively. Chloroquine and its metabolite desethyl chloroquine, quinine, sulfadoxine and primaquine do not interfere in the detection of amodiaquine, desethyl amodiaquine and bisdesethyl amodiaquine in plasma.