Modeling (1H) exchange: an estimate of the error introduced in MRI by assuming the fast exchange limit in bolus
1Medical Physics and Applied Radiation Sciences Unit, McMaster University, Hamilton, Ontario, Canada. morang@mcmaster.ca
Abstract:
A simulation is presented which calculates the MRI signal expected from a model tissue for a given pulse sequence after a bolus injection of a contrast agent. The calculation assumes two physiologic compartments only, the intravascular and extravascular spaces. The determination of the concentration of contrast in each compartment as a function of time and position has been outlined in a previous publication (Moran and Prato, Magn Reson Med 2001;45:42-45). These contrast agent concentrations are used here to determine the NMR relaxation times as a function of time and position within the tissue. Knowledge of this simulated tissue 'map' of relaxation times as a function of time provides the information required to determine whether the proton exchange rate is fast or slow on the NMR timescale. Since with a bolus injection the concentration of contrast and hence the relaxation time may vary with position along the capillary, some segments of the capillary are allowed to be in fast exchange with the extravascular space, while others may be in slow exchange. Using this information, and parameters specific to a given tissue, the MRI signal for a given pulse sequence is constructed which correctly accounts for differences in proton exchange across the length of the capillary. It is shown that extravascular contrast agents show less signal dependence on water exchange, and thus may be more appropriate for quantitative imaging when using fast exchange assumptions. It is also shown that nondistributed compartment models can incorrectly estimate the water exchange that is occurring at the capillary level if exchange-minimizing pulse sequences are not used.
More Related Videos
06:24Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...