Determination of bisphenol A diglycidyl ether and its hydrolysis and chlorohydroxy derivatives by liquid

Raquel Sendón García1, Perfecto Paseiro Losada

  • 1Analytical Chemistry, Nutrition and Bromatology Department, Pharmacy Faculty, Campus Sur University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.

Related Concept Videos

Hydrolysis of Chlorobenzene to Phenol: Dow Process01:10

Hydrolysis of Chlorobenzene to Phenol: Dow Process

Simple aryl halides do not react with nucleophiles under normal conditions. However, the reaction can proceed under drastic conditions involving high temperatures and high pressure to give the substituted products. For example, chlorobenzene is converted to phenol using aqueous sodium hydroxide at 350 °C under high pressure by the Dow process. The reaction follows an elimination-addition mechanism involving a benzyne intermediate. Here, the chloride ion is eliminated to generate the benzyne...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Mass Spectrometry: Cycloalkane Fragmentation01:05

Mass Spectrometry: Cycloalkane Fragmentation

In mass spectrometry, cycloalkanes exhibit distinct fragmentation patterns due to the inherent stability of their molecular ions compared to linear or branched alkanes. The ring structure of cycloalkanes provides additional stability to the molecular ions, often resulting in prominent ion peaks in the mass spectrum.
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Mass Spectrometry: Cycloalkene Fragmentation00:54

Mass Spectrometry: Cycloalkene Fragmentation

The molecular ions of cycloalkenes undergo fragmentation via a retro-Diels–Alder reaction.
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...