Related Experiment Video
Updated: Aug 15, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Micellar electrokinetic chromatography for the simultaneous determination of ketorolac tromethamine and its
S Orlandini1, S Fanali, S Furlanetto
1Department of Pharmaceutical Sciences, Via G. Capponi 9, 50121 Florence, Italy.
Abstract:
A simple, fast and selective micellar electrokinetic chromatographic (MEKC) method for the simultaneous assay of ketorolac tromethamine and its known related impurities (1-hydroxy analog of ketorolac, 1-keto analog of ketorolac and decarboxylated ketorolac), in both drug substance and coated tablets, is described. The compounds were detected at 323 nm, and flufenamic acid (FL) and tolmetin (TL) were chosen as internal standards to quantify ketorolac tromethamine and impurities, respectively. The multivariate optimization of the experimental conditions was carried out by means of the response surface study, considering as responses the resolution values and analysis time. The optimized background electrolyte (BGE) consisted of a mixture of 13 mM boric acid and phosphoric acid, adjusted to pH 9.1 with 1 M sodium hydroxide, containing 73 mM sodium dodecyl sulfate (SDS). Optimal temperature and voltage were 30 degrees C and 27 kV. Applying these conditions, all compounds were resolved in about 6 min. The related substances could be quantified up to the 0.1% (w/w) level. Validation was performed, either for drug substances and drug product, evaluating selectivity, robustness, linearity and range, precision, accuracy, detection and quantitation limits and system suitability.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations