Abstract:
Air sampling performed during 190 Tc-labeled DTPA aerosol lung ventilation studies indicated that the maximum airborne concentration to which the nuclear medicine technologists might be exposed was 7.1 x 10(-1) Bq mL(-1) (1.9 x 10(-5) microCi mL(-1)). If a single technologist performed ALL the aerosol studies, at this maximum airborne concentration, based on the Annual Limit on Intake (ALI), the resulting dose equivalents could be either 1 mSv (100 mrem) to the lungs or 0.1 mSv (10 mrem) to the total body. However, the procedures are shared by the technical staff, the times of exposure are represented by only a fraction of the overall procedure time, and the average airborne concentrations were found to be more than an order of magnitude lower than the maximum. This resulted in a projected average annual dose equivalent of 7.0 x 10(-3) mSv (0.7 mrem) to the lungs or 7.0 x 10(-4) mSv (0.07 mrem) to the whole body from the performance of these procedures.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT