Background:
MRI has been proposed for non-invasive detection and quantification of liver iron content, but has not been validated as a reproducible and sensitive method, especially in patients with mild iron overload. We aimed to assess the accuracy of a simple, rapid, and easy to implement MRI procedure to detect and quantify hepatic iron stores.
Methods:
Of 191 patients recruited, 17 were excluded and 174 studied, 139 in a study group and 35 in a validation group. All patients underwent both percutaneous liver biopsy with biochemical assessment of hepatic iron concentration (B-HIC) and MRI of the liver with various gradient-recalled-echo (GRE) sequences obtained with a 1.5 T magnet. Correlation between liver to muscle (L/M) signal intensity ratio and liver iron concentration was calculated. An algorithm to calculate magnetic resonance hepatic iron concentration (MR-HIC) was developed with data from the study group and then applied to the validation group.
Findings:
A highly T2-weighted GRE sequence was most sensitive, with 89% sensitivity and 80% specificity in the validation group, with an L/M ratio below 0.88. This threshold allowed us to detect all clinically relevant liver iron overload greater than 60 micromol/g (normal value <36 micromol/g). With other sequences, an L/M ratio less than 1 was highly specific (>87%) for raised hepatic iron concentration. With respect to B-HIC range analysed (3-375 micromol/g), mean difference and 95% CI between B-HIC and MR-HIC were quite similar for study and validation groups (0.8 micromol/g [-6.3 to 7.9] and -2.1 micromol/g [-12.9 to 8.9], respectively).
Interpretation:
MRI is a rapid, non-invasive, and cost effective technique that could limit use of liver biopsy to assess liver iron content. Our MR-HIC algorithm is designed to be used on various magnetic resonance machines.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging