Related Experiment Video
Updated: Aug 24, 2026

Autoradiography as a Simple and Powerful Method for Visualization and Characterization of Pharmacological Targets
Published on: March 12, 2019
Impact of 131I diagnostic activities on the biokinetics of thyroid remnants
Michael Lassmann1, Markus Luster, Heribert Hänscheid
1Klinik und Poliklinik für Nuklearmedizin der Universität Würzburg, Würzburg, Germany. lassmann@nuklearmedizin.uni-wuerzburg.de
Unlabelled:
Recent publications described many discrepant findings about thyroid "stunning" after the administration of (131)I diagnostic activities to patients with differentiated thyroid carcinoma. Stunning may play a major role in reducing the therapeutic efficacy of high (131)I activities given for ablation therapy.
Methods:
Participation in a multicenter study to investigate differences in iodine biokinetics in the hypothyroid state and after the application of recombinant human thyroid-stimulating hormone enabled us to study quantitative changes in thyroid iodine biokinetics after the administration of 74 MBq of (131)I twice within 6 wk and an ablation activity of 3-4 GBq 7-12 d after the second diagnostic administration of (131)I in 6 patients.
Results:
The uptake and half-life of the first 74 MBq of (131)I were significantly reduced to a mean of 44% and a mean of 51%, respectively, after the second diagnostic administration and further reduced to a mean of 40% and a mean of 30%, respectively, during ablation therapy. The residence times were reduced to 25% in the second dosimetric assessment and to 10% during therapy compared with the value in the first assessment. For one patient, an estimated absorbed dose as high as 38 Gy was found in the first diagnostic study. The mean dose for all patients after the first assessment was 15 Gy; after each further assessment, the dose was reduced according to the decrease in residence time.
Conclusion:
This study shows a severe impact of 74 MBq of (131)I on the biokinetics of thyroid remnants during subsequent radioiodine therapy.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Graves Disease II: Pathophysiology