Related Experiment Video
Updated: Aug 24, 2026

The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
Published on: August 12, 2013
Simultaneous absolute measurements of principal angle and phase retardation with a new common-path heterodyne
Yu-Lung Lo1, Chun-Hau Lai, Jing-Fung Lin
1Department of Mechanical Engineering, National Cheng Kung University, Tainan, Taiwan. loyl@mail.ncku.edu.tw
Abstract:
This study demonstrates a new method for simultaneously measuring both the angle of the principal axis and the phase retardation of the linear birefringence in optical materials. We used a circular common-path interferometer (polariscope) as the basic structure modulated by an electro-optic (EO) modulator. An algorithm was developed to simultaneously measure the principal axis and the phase retardation of a lambda/4 or lambda/8 plate as a sample. In the case of a lambda/4 plate, the average absolute error of the principal axis is approximately 3.77 degrees, and that of the phase retardation is approximately 1.03 degrees (1.09%). The retardation error is within the 5% uncertainty range of a commercial wave plate. Fortunately, the nonlinear error caused by the reflection phase retardation of the beam splitter dose not appear in the new system. Therefore the error could be attributed to misalignment and defects in the EO modulator or the other optical components. As for the repeatability of this new common-path heterodyne interferometer, the average deviation for the principal axis is 0.186 degrees and the phase retardation is 0.356 degrees. For the stability, the average deviation for the principal axis is 0.405 degrees and the phase retardation is 0.635 degrees. The resolution of this new system is estimated to be approximately 0.5 degrees, and the principal axis and phase retardation could be measured up to pi and 2pi, respectively, without ambiguity.
Related Concept Videos
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...

