Validation of diagnostic tests for determination of magnesium status in horses with reduced magnesium intake
Allison J Stewart1, Joanne Hardy, Catherine W Kohn
1Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH 43210, USA.
Objective:
To evaluate the diagnostic value of serum concentrations of total magnesium (tMg) and ionized magnesium (iMg), concentrations of magnesium (Mg) in muscle, intracellular Mg (icMg) concentrations, urinary Mg excretion (EMg), Mg clearance (CMg), and fractional clearance of Mg (FCMg) in horses fed diets with Mg content above and below National Research Council recommendations.
Animals:
9 young female horses.
Procedures:
6 horses were fed a reduced-Mg diet for 29 days followed by an Mg-supplemented diet for 24 days. Control horses (n = 3) were fed grass hay exclusively. Blood, urine, and tissue samples were collected, and an Mg retention test was performed before and after restriction and supplementation of Mg intake. Serum tMg, serum iMg, muscle Mg, icMg, and urine Mg concentrations were measured, and 24-hour EMg, CMg, and FCMg were calculated.
Results:
Reductions in urinary 24-hour EMg, CMg, and FCMg were evident after 13 days of feeding a reduced-Mg diet. Serum tMg and iMg concentrations, muscle Mg content, and results of the Mg retention test were not affected by feeding the Mg-deficient diet. Spot urine sample FCMg accurately reflected FCMg calculated from 6- and 24-hour pooled urine samples. Mean +/- SD FCtMg of horses eating grass hay was 29 +/- 8%, whereas mean FCtMg for horses fed a reduced-Mg diet for 29 days was 6 +/- 3%.
Conclusions And Clinical Relevance:
The 24-hour EMg was the most sensitive indicator of reduced Mg intake in horses. Spot sample FCMg can be conveniently used to identify horses consuming a diet deficient in Mg.
Related Concept Videos
Qualitative Analysis
For instance, group IV...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Serum Laboratory Studies, Stool Test, Breath Test