Related Experiment Video
Updated: Aug 24, 2026

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Validity and reliability of the Motion Sensitivity Test
Faith W Akin1, Mary Jo Davenport
1Auditory and Vestibular Dysfunction Research Enhancement Award Program, Audiology and Speech Pathology Service, James H. Quillen VA Medical Center, Mountain Home, TN 37684, USA. faith.akin@med.va.gov
Abstract:
The Motion Sensitivity Test (MST) is a clinical protocol designed to measure motion-provoked dizziness during a series of 16 quick changes to head or body positions. The MST has been used as a guide for developing an exercise program for patients with motion-provoked dizziness and as a treatment outcome measure to monitor the effectiveness of vestibular rehabilitation therapy. This study determined validity, test-retest reliability, and interrater reliability of the MST. Fifteen individuals with motion-provoked dizziness and ten control individuals were tested during sessions occurring 90 min and/or 24 hr after baseline testing. The MST was found to be reliable across raters (intraclass correlation coefficient [ICC] = 0.99) and test sessions (ICC = 0.98 and 0.96). Test validity was good. The results indicated that the MST can be used reliably in clinical practice to develop exercise programs for patients with motion-provoked dizziness and to provide evidence of intervention efficacy.