Related Experiment Video
Updated: Aug 24, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Cardiac output determination during experimental hemorrhage and resuscitation using a transesophageal Doppler monitor
Luiz Francisco Poli de Figueiredo1, Ruy Jorge Cruz, Eliezer Silva
1Division of Applied Physiology, InCor-Heart Institute, University of São Paulo Medical School, São Paulo, Brazil. expluiz@incor.usp.br
Abstract:
Transesophageal Doppler (TED) monitoring has been considered a noninvasive and accurate alternative to pulmonary artery catheterization for volume replacement and cardiac output measurement in patients undergoing major surgery. This study tested the hypothesis that TED can accurately predict cardiac output during hemorrhage, shock, and resuscitation, by comparing it to total pulmonary artery blood flow (PABF) and to standard intermittent bolus cardiac output (ICO). In eight anesthetized dogs (18 +/- 1.0 kg), PABF was measured with an ultrasonic flowprobe while ICO and mixed venous O2 saturation (SvO2) were measured through a Swan-Ganz catheter. A TED probe (CardioQ, Deltex Medical Inc., Irving, TX, U.S.A.), designed for adult use (minimum 30 kg, 16 years), was placed in midesophageous to evaluate stroke volume. A graded hemorrhage (20 mL/min) was produced (H5-H35) to a mean arterial pressure (MAP) of 40 mm Hg and maintained by additional blood removal for 30 min (S1-S30). Total shed blood volume was retransfused (541 +/- 54.2 mL) over 30 min (T5-T30), after which a massive hemorrhage, 100 mL/min rate, was produced over 10 min (MH5-MH10). In general, TED overestimated PABF (r2 = 0.3472), but changes in TED paralleled PABF throughout the experimental protocol, particularly during massive hemorrhage (r2 = 0.9001). We concluded that TED accurately reflected the direction and magnitude of the changes of cardiac output over time during abrupt hemodynamic changes. Probes designed for lower weights and smaller aortas may improve its accuracy in medium size animal models under less dramatic alterations induced by hemorrhage, shock, and resuscitation.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
