Related Experiment Video
Updated: Aug 24, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Kinematics of the upper cervical spine in rotation: in vivo three-dimensional analysis
Takahiro Ishii1, Yoshihiro Mukai, Noboru Hosono
1Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Suita, Japan. ishii-takahiro88@umin.ac.jp
Study Design:
Kinematics of the upper cervical spine during head rotation were investigated using three-dimensional magnetic resonance imaging (MRI) in healthy volunteers.
Objectives:
To demonstrate in vivo intervertebral coupled motions of the upper cervical spine.
Summary Of Background Data:
Although various in vivo and in vitro studies have identified the normal movement patterns of the upper cervical spine, no previous studies have accurately analyzed in vivo three-dimensional intervertebral motions of the upper cervical spine during head rotation.
Methods:
Fifteen healthy volunteers underwent three-dimensional MRI of the upper cervical spine using a 1.0-T imager in progressive 15 degrees steps during head rotation. Segmented three-dimensional MRIs of each vertebra in the neutral position were superimposed over images taken at other positions, using voxel-based registration. Relative motions between occiput (Oc) and atlas (C1) and between C1 and axis (C2) were measured and described with 6 degrees of freedom by rigid body Euler angles and translations.
Results:
Mean (+/- SD) maximum angles of axial rotation in Oc-C1 and C1-C2 were 1.7 +/- 1.5 degrees and 36.2 +/- 4.5 degrees to each side, respectively. Increases in angle of axial rotation in C1-C2 became smaller with increased head rotation, indicating axial rotation in C1-C2 displayed nonlinear motion. Coupled lateral bending with axial rotation was observed in the direction opposition to that of axial rotation in Oc-C1 (mean, 4.1 +/- 1.4 degrees) and C1-C2 (mean, 3.8 +/- 3.0 degrees). Coupled extension with axial rotation occurred at both C0-C1 (mean, 13.3 +/- 4.9 degrees) and C1-C2 (mean, 6.9 +/- 3.0 degrees).
Conclusions:
We developed an innovative in vivo three-dimensional motion analysis system using three-dimensional MRI. In vivo coupled motions of the upper cervical spine investigated using this system supported the results of the previous in vitro study.
Related Concept Videos
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Articulations of the Vertebral Column
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it instrumental in...
Rotation with Constant Angular Acceleration - II
The first...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...