Related Experiment Video
Updated: Aug 21, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Recent developments in cardiac output determination by bioimpedance: comparison with invasive cardiac output and
Yaron Moshkovitz1, Edo Kaluski, Olga Milo
1Cardiac Surgery Department, Ramat Marpe Hospital, Petah Tikva, Israel.
Purpose Of Review:
To describe recent developments in bioimpedance technique and its application in cardiovascular diseases. Cardiac output determination has been used selectively during recent years because of the need for invasive right heart catheterization. Hence, experience with its application in patients with cardiovascular diseases and especially heart failure is limited. Bioimpedance is a novel noninvasive technique determining changes in instantaneous (during one heartbeat) conductance of a small electrical current transferred through the body. By using different algorithms correcting for various body composition constants, it calculates the change in instantaneous arterial blood volume (that is, stroke volume) and cardiac output. Traditionally, bioimpedance cardiac output is determined using either thoracic or whole body techniques according to the location of the electrodes transmitting and receiving the small electrical current.
Recent Findings:
Significant progress was achieved in recent years in cardiac output determination by bioimpedance. Newer algorithms using thoracic and whole body bioimpedance have demonstrated better correlation with invasive cardiac output determination. In a few preliminary studies bioimpedance-determined cardiac output was found useful in the diagnosis, risk stratification, and treatment titration of some cardiovascular conditions. Further, larger prospective studies are required to determine the true independent value of cardiac output measurement by bioimpedance for the evaluation of cardiovascular diseases and especially heart failure.
Summary:
Recently, significant improvement was achieved in cardiac output measurement by bioimpedance with both newer thoracic and whole body techniques. Preliminary studies imply that this measure may be of value in managing some cardiovascular disorders.
More Related Videos
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pathophysiology of Cardiac Performance
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...