Related Experiment Video
Updated: Aug 24, 2026

Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Update for nurse anesthetists. The Starling resistor: a model for explaining and treating obstructive sleep apnea
1Virginia Commonwealth University, Richmond, Va., USA.
Abstract:
Recent epidemiological research places the incidence of obstructive sleep apnea as high as 16% in the general population. Serious postoperative respiratory complications and death have been reported in this population. Anesthetic drugs contribute to these complications secondary to acute and residual influences on the complex orchestration of airway muscles and reflexes involved in airway patency. The Starling resistor model is a theoretical model that has application in explaining upper airway dynamics and the treatment and management of obstructive sleep apnea. The model postulates the oropharynx as a collapsible tube. The oropharynx remains open or partially or completely closed as a result of pressure upstream at the nose and mouth, pressure downstream at the trachea and below, or tissue pressure surrounding the oropharynx. This AANA Journal course provides an overview of the Starling resistor model, its application to obstructive sleep apnea, and preoperative and postoperative anesthetic considerations.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...

