Purpose:
To set Diagnostic Reference Levels (DRLs) in interventional radiology by means of dose area product (DAP) measurements and the grouping of homogeneous procedures, and to quantify the associated errors in the DRL estimates. To evaluate the Mean Effective Doses per single procedure.
Materials And Methods:
Interventional radiology procedures were divided into four main groups: neuroradiological, vascular, extravascular and paediatric. Neuroradiological and vascular procedures were further divided into diagnostic and interventional procedures. Starting from DAP and total fluoroscopy time measurements in 1,256 patients, the DRLs were determined for 17 procedures, together with an estimate of their uncertainty. The correlation between fluoroscopy time and DAP was assessed. Mean effective dose estimates were obtained from measured DAP values and from the analysis of the dosimetric data reported in the literature for similar procedures.
Results:
The main features of DAP distributions are long high-dose tails, indicating asymmetric distributions, together with a large interquartile range. Rounded third-quartile values of DAP distributions showed a large range in the procedures taken into consideration. Values of 147, 198, 338 Gy cm(2)were obtained for supra-aortic angiography, cerebral angiography and embolization. Values of 86-101 and 459-438 Gy cm(2)were obtained for diagnostic and interventional vascular procedures on the lower limbs and on the abdomen, respectively. Values of 25-33 Gy cm(2)were obtained for retrograde cystourethrographies and ERCP, and values of 62-158 Gy cm(2)were obtained for nephrostomy and percutaneous transhepatic cholangiography. The correlation between total fluoroscopy time and the DAP values was poor. Mean effective dose estimates showed lower values for extravascular procedures (4.8-28.2 mSv), intermediate values for neuroradiological procedures (12.6-32.9 mSv) and higher values for vascular procedures involving the abdomen (36.5-86.8 mSv).
Discussion:
DAP values were generally higher in vascular than in extravascular procedures. In generally, interventional vascular procedures show higher DAP values than the corresponding diagnostic procedures, with the exception of the abdominal region where the values were similar. Extravascular procedures with percutaneous access show significantly higher DAP values than those with endoscopic access. Total fluoroscopy time is a poor predictor of patient doses in interventional radiology.
Conclusions:
The systematic recording of DAP values, together with adequate grouping of similar procedures makes it possible to establish stable DRLs on a local basis and to carry out dosimetric evaluations, although on a statistical rather than individual basis. Patient radiation doses during interventional radiological procedures may be high, particularly when the abdominal region is involved.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET