Related Experiment Video
Updated: Aug 16, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery
1Department of Radiology, Orebro University Hospital, 701 85 Orebro, Sweden. hakan.geijer@orebroll.se
Abstract:
The aim of this study was to evaluate radiation dose and patient discomfort/pain in radial artery access vs femoral artery access in percutaneous coronary intervention (PCI). Dose-area product (DAP) was measured non-randomised for 114 procedures using femoral access and for 55 using radial access. The patients also responded to a questionnaire concerning discomfort and pain during and after the procedure. The mean DAP was 69.8 Gy cm(2) using femoral access and 70.5 Gy cm(2) using radial access. Separating the access site from confounding factors with a multiple regression, there was a 13% reduction in DAP when using radial access (p=0.038). Procedure times did not differ (p=0.81). Bed confinement was much longer in the femoral access group (448 vs 76 min, p=0.000). With femoral access, there was a significantly higher patient grading for chest (p=0.001) and back pain (p=0.003) during the procedure and for access site (p=0.000) and back pain (p=0.000) after the procedure. Thirty-two femoral access patients (28%) were given morphine-type analgesics in the post-procedure period compared to three radial access patients (5%, p=0.001). DAP does not increase when using radial instead of femoral access and the patients grade discomfort and pain much lower when using radial access. Radial access is thus beneficial to use.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Imaging Studies VII: Vascular Imaging