Related Experiment Video
Updated: Aug 24, 2026

Visualization of miniSOG Tagged DNA Repair Proteins in Combination with Electron Spectroscopic Imaging (ESI)
Published on: September 24, 2015
Voltammetric behavior of DNA modified with osmium tetroxide 2,2'-bipyridine at mercury electrodes
Ludek Havran1, Miroslav Fojta, Emil Palecek
1Institute of Biophysics, Academy of Sciences of Czech Republic, Královopolská 135,CZ-612 65, Brno, Czech Republic. raven@ibp.cz
Abstract:
Osmium tetroxide complexes with nitrogen ligands (L) are probes of DNA structure and electroactive labels of DNA. Here adducts of single-stranded (ss) DNA with osmium tetroxide 2,2'-bipyridine (DNA-Os,bipy) were studied by cyclic voltammetry for the first time. It was found that at neutral pH DNA-Os,bipy produces three redox couples in the potential range between 0 and -1 V (peaks I-III) and a cathodic peak at about -1.3 V (peak IV). The latter peak decreased with increasing scan rate, and peaks arising from the forward and reverse scans exhibited the same direction, suggesting catalytic nature of the electrode process. We concluded that this peak corresponds to the known differential pulse voltammetric (polarographic) peak of DNA-Os,L adducts for which catalytic hydrogen evolution is responsible. In contrast, currents of cathodic peaks II and III increased almost linearly with increasing scan rate, suggesting involvement of adsorption in the electrode processes. Adsorptive stripping square-wave voltammetry was used to analyze the DNA-Os,bipy at low concentrations. It was shown that at neutral pH, peak III can offer sensitivity in the ppb range, which is only little lower than that reached by catalytic peak IV. The latter peak is, however, superior in sensitivity at acid pH values.
More Related Videos
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
06:53Magnetometric Characterization of Intermediates in the Solid-State Electrochemistry of Redox-Active Metal-Organic Frameworks
Published on: June 9, 2023
Related Concept Videos
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetric Techniques: Cyclic Voltammetry
Voltammetric Techniques: Pulse Voltammetry
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Factors Affecting Measurements