Evidence for the interaction of technetium colloids with humic substances by X-ray absorption spectroscopy

A Maes1, K Geraedts, C Bruggeman

  • 1Departement Interfasechemie, Katholieke Universiteit Leuven, Kasteelpark Arenberg 23, B-3001 Heverlee, Belgium. andre.maes@agr.kuleuven.ac.be

Related Concept Videos

Interaction of EM Radiation with Matter: Spectroscopy01:12

Interaction of EM Radiation with Matter: Spectroscopy

Electromagnetic (EM) radiation can be considered an oscillating electric and magnetic field propagating through a medium that can interact with matter in its path. The electric field in the radiation can interact with electrical charges in the atoms or molecules in the matter. On the other hand, the magnetic field can interact with the magnetic field in the atomic nucleus. The study of the interaction between electromagnetic radiation and matter is termed spectroscopy. Spectroscopy is the study...
2D NMR: Overview of Heteronuclear Correlation Techniques01:18

2D NMR: Overview of Heteronuclear Correlation Techniques

Heteronuclear correlation spectroscopy is an analytical technique that investigates the coupling between different types of nuclei, often a proton and an X-nucleus, such as carbon-13 or nitrogen-15. This method is commonly used in nuclear magnetic resonance (NMR) spectroscopy to gain insights into complex chemical compounds' structural and compositional aspects. A typical heteronuclear correlation spectrum displays X-nucleus chemical shifts on one axis and a proton spectrum on the other axis.
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...