Related Experiment Video
Updated: Aug 24, 2026

Synthesis and Characterization of Supramolecular Colloids
Published on: April 22, 2016
Evidence for the interaction of technetium colloids with humic substances by X-ray absorption spectroscopy
A Maes1, K Geraedts, C Bruggeman
1Departement Interfasechemie, Katholieke Universiteit Leuven, Kasteelpark Arenberg 23, B-3001 Heverlee, Belgium. andre.maes@agr.kuleuven.ac.be
Abstract:
Spectroscopic extended X-ray absorption fine structure (EXAFS) evidence was obtained on the chemical environment of 99Tc(IV) atoms formed upon introduction of TcO4- into four types of laboratory-scale synthetic and natural systems which mimic in situ natural reducing conditions in humic-rich geochemical environments: (a) magnetite/pyrite in synthetic groundwater in the absence of humic substances (HSs), (b) magnetite/pyrite in natural Gorleben groundwater in the presence of HSs, (c) Boom clay sediment mixed with synthetic groundwater, and (d) Gorleben sand mixed with natural Gorleben groundwater. The investigated systems obey to pH 8-9 conditions, and all measured samples show similar EXAFS spectra for Tc, which could be fitted by a hydrated TcO2 x xH2O phase. The results are interpreted as follows: upon introduction of high concentrations (millimolar to micromolar) of TcO4-to chemically reducing environments, small Tc(IV) oxidic polymers are formed, which either may aggregate into larger units (colloids) and finally precipitate or may interact in their polymeric form with (dissolved and immobile) humic substances. This latter type of interaction--Tc(IV) colloid sorption onto HSs--differs significantly from the generally accepted metal--humate complexation and therefore offers new views on the possible reaction pathways of metals and radionuclides in humic-rich environments.
More Related Videos
Related Concept Videos
Interaction of EM Radiation with Matter: Spectroscopy
2D NMR: Overview of Heteronuclear Correlation Techniques
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...

