Pancreas preservation with University of Wisconsin and Celsior solutions: a single-center, prospective, randomized
Ugo Boggi1, Fabio Vistoli, Marco Del Chiaro
1Divisione di Chirurgia Generale e Trapianti, Dipartimento di Oncologia, Trapianti e Nuove Tecnologie in Medicina, Università di Pisa, Pisa, Italy. u.boggi@med.unipi.it
Background:
Celsior is an extracellular-type, low-viscosity, preservation solution already used for heart, lung, liver, and kidney transplantation. We report the results of a single-center, prospective, randomized pilot study specifically designed to compare the safety profile of Celsior solution with University of Wisconsin (UW) solution in clinical pancreas transplantation.
Methods:
A total of 105 consecutive procurements were randomized to graft preservation with UW (n=53) solution or Celsior (n=52) solution. The groups were comparable with regard to all donor and recipient characteristics.
Results:
Five grafts were discarded and 100 grafts (50 UW vs. 50 Celsior) were transplanted. Mean cold and warm ischemia times were 11.0 +/- 2.1 hr and 37.2 +/- 6.0 min for UW compared with 10.8 +/- 1.8 hr and 38.1 +/- 5.9 min for Celsior (P =not significant). Delayed endocrine pancreas function was recorded in one graft preserved with UW solution. Eleven recipients (UW 12% vs. Celsior 10%, P =not significant) required a relaparotomy. The mean serum levels of glucose, amylase, and lipase remained comparable between the study arms at equivalent intervals after transplantation. One recipient died with functioning grafts in each study arm; two further grafts were lost to arterial thrombosis (Celsior) and chronic rejection (UW), respectively. Actuarial 1-year patient and graft survival rates overlapped in the two study arms (98% and 96%, respectively).
Conclusions:
Within the range of cold ischemia time reported in this study, UW and Celsior solutions have similar safety profiles for pancreas preservation.