Design, fabrication, and evaluation of microfabricated columns for gas chromatography
Gordon Lambertus1, Andrea Elstro, Kathryn Sensenig
1Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, USA.
Abstract:
The design, fabrication, and performance of gas chromatography columns etched in silicon substrates are described. Deep reactive-ion etching formed the 3-m-long, 150-microm-wide, 240-microm-deep rectangular cross section channels. A glass cover plate was anodically bonded to the remaining surface of the substrate forming the gastight channel. For some of the columns, the silicon channels were oxidized before the channels were sealed with the glass plates. Fused-silica capillary connecting tubes were sealed into ports on the edge of the 3.2-cm x 3.2-cm substrate chips. Dynamic coating was used to deposit a film of nonpolar dimethyl polysiloxane or moderately polar trifluoropropylmethyl polysiloxane stationary phase. The columns were evaluated in a conventional benchtop GC instrument with split injection and flame ionization detection. Column efficiency was evaluated by the use of plots of height equivalent to a theoretical plate versus average carrier gas velocity using both hydrogen and air as carrier gases. The number of theoretical plates measured at the average carrier gas velocity giving the minimum plate height ranged from 4600 to 8200 plates for the dimethyl polysiloxane columns and from 3500 to 5500 plates for the trifluoropropylmethyl polysiloxane columns. Minimum plate height was significantly smaller with air as carrier gas. For the nonpolar phase, the nonoxidized surface gave approximately 1500 plates more than the oxidized surface for both carrier gases. For the polar phase, the oxidized surface gave approximately 200 plates more than the nonoxidized surface. Isothermal chromatograms of a 20-component multifunctional mixture and temperature-programmed chromatograms of a normal alkane mixture are presented.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...