Related Experiment Video
Updated: Aug 24, 2026

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Coronoid process and radial head as posterolateral rotatory stabilizers of the elbow
Alberto G Schneeberger1, Michel M Sadowski, Hilaire A C Jacob
1Department of Orthopaedic Surgery, University of Zurich, Balgrist, Zurich, Switzerland. alberto.schneeberger@balgrist.ch
Background:
The purpose of this study was to evaluate the role of the radial head and the coronoid process as posterolateral rotatory stabilizers of the elbow and to determine the stabilizing effect of radial head replacement and coronoid reconstruction.
Methods:
The posterolateral rotatory displacement of the ulna was measured after application of a valgus and supinating torque (1). in seven intact elbows, (2). after radial head excision, (3). after sequential resection of the coronoid process, (4). after subsequent insertion of each of two different types of metal radial head prostheses (a rigid implant and a bipolar implant with a floating cup), and (5). after subsequent reconstruction of the coronoid with each of two different techniques in the same cadaveric elbow.
Results:
The posterolateral rotatory laxity averaged 5.4 degrees in the intact elbows. The surgical approach used in this study insignificantly increased the mean laxity to 9 degrees. Excision of the radial head in an elbow with intact collateral ligaments caused a mean posterolateral rotatory laxity of 18.6 degrees (p < 0.0001). Additional removal of 30% of the height of the coronoid fully destabilized the elbows, always resulting in ulnohumeral dislocation despite intact ligaments. Implantation of a rigid radial head prosthesis stabilized the elbows. However, a mean laxity of 16.9 degrees persisted after insertion of a floating prosthesis (p < 0.0001). The elbows with a defect of 50% or 70% of the coronoid, loss of the radial head, and intact ligaments could not be stabilized by radial head replacement alone, but additional coronoid reconstruction restored stability.
Conclusions:
The results of this study suggest that the coronoid and the radial head contribute significantly to posterolateral rotatory stability.
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Humerus
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Arteries of the Upper Limbs
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...
