Bactericidal effects of acidic electrolyzed water on the dental unit waterline
Shinya Kohno1, Toshitsugu Kawata, Masato Kaku
1Department of Orthodontics and Craniofacial Developmental Biology, Hiroshima University, Hiroshima 734-8553, Japan. acho@hiroshima-u.ac.jp
Abstract:
Many studies have been conducted in the United States regarding the microbial contamination of dental unit waterline, but not in Japan. Recently, acidic electrolyzed water has been used in the medical and dental fields. In this study, we investigated the bactericidal effects of the temporary inflow of acidic electrolyzed water on microbial contamination of the dental unit waterline. First, in order to observe the daily bacterial contamination of the dental unit waterline, water samples were collected at the end of handpieces and three-way syringes before the inflow of acidic electrolyzed water. They were cultured to detect viable bacteria. Later, the inflow of acidic electrolyzed water was conducted through the piping box of the dental unit. Before starting operation on next day, water samples were collected and cultured, as described above. The mean viable bacteria count was 910 -/+ 190 CFU/ml at the end of handpieces, and 521 -/+ 116 CFU/ml at the end of three-way syringes before the inflow of acidic electrolyzed water. However, bacteria were detected in only small numbers at the end of handpieces and three-way syringes on the next day. These results indicated that acidic electrolyzed water could be applied as an appropriate measure against bacterial contamination of the dental unit waterline.
Related Concept Videos
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Electrolysis
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation: