Raman and IR Spectroelectrochemical Methods as Tools to Analyze Conjugated Organic Compounds
Published on: October 12, 2018
Simultaneous EQCM and diffuse reflectance UV-visible spectroelectrochemical measurements:
Ling Jiang1, Qingji Xie, Ling Yang
1Key Laboratory of Chemical Biology & Traditional Chinese Medicine Research (Hunan Normal University), Ministry of Education, Hunan Normal University, Changsha 410081, People's Republic of China.
Abstract:
Piezoelectric diffuse reflectance spectroelectrochemistry (PDRSEC), a new technique of diffuse reflectance spectroelectrochemistry (DRSEC) in combination with electrochemical quartz crystal microbalance (EQCM), was developed to study the electrochemical copolymerization of aniline and o-anthranilic acid in 1.0 mol l(-1) HClO4 and the properties of these copolymers. The DRSEC using an integral sphere was proven to possess a higher optical sensitivity at the unpolished piezoelectric quartz crystal electrodes used than the mirror reflectance spectroelectrochemistry mode. The copolymers grown from the copolymerization bath of different molar fractions of o-anthranilic acid (F1, relative to the total amount of the two monomers) showed intermediate properties between those of the homopolymers, which varied gradually with F1. The swelling/dissolution behavior of the copolymers vs solution pH was traced via the EQCM frequency and resistance signals, and its large dependence on F1 was found and discussed. In a HAc-NaAc buffer solution at pH 5.6, the amount of adsorbed lysozyme was found to be positively correlated with F1, via an EQCM impedance investigation, demonstrating the feasibility of using poly(aniline-co-o-anthranilic acid) as a load-adjustable immobilization matrix for cationic proteins. The novel PDRSEC method proposed is highly recommended for surface electrochemistry studies at relatively rough electrodes.
More Related Videos
Related Concept Videos
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Measuring Reaction Rates