Inter-molecular migration during collisional activation monitored by hydrogen/deuterium exchange FT-ICR tandem mass

Charlotte Hagman1, Per Håkansson, Jos Buijs

  • 1Department of Engineering Sciences, Division of Ion Physics, Uppsala University, Uppsala, Sweden. Charlotte.Hagman@angstrom.uu.se

Related Concept Videos

Tandem Mass Spectrometry01:21

Tandem Mass Spectrometry

Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Radical Reactivity: Intramolecular vs Intermolecular01:33

Radical Reactivity: Intramolecular vs Intermolecular

Radical reactions can occur either intermolecularly or intramolecularly. In an intermolecular radical reaction, a nucleophilic radical adds to an electrophilic alkene or vice versa. In such reactions, the radical and generally the alkene, which is also called the radical trap, are two different molecules. Additionally, for such intermolecular reactions to occur, the radical trap must be active, present in an excess concentration, and the radical starting material must have a weak carbon–halogen...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Activation of Integrins01:15

Activation of Integrins

Integrins bind ligands and transmit information from outside the cell to inside or vice-versa through an "outside-in signaling" or "inside-out signaling."
In "outside-in signaling," external factors in the extracellular space bind to exposed ligand binding sites on integrins. This causes the inactive protein to undergo a conformational change to become active. Integrins are often clustered on the cell membrane. Repetitive and regularly spaced ligand binding events provide an effective stimulus.
¹H NMR of Labile Protons: Deuterium (²H) Substitution00:48

¹H NMR of Labile Protons: Deuterium (²H) Substitution

This lesson illustrates the role of deuterium substitution in simplifying the NMR spectrum of compounds comprising labile protons. One method employed is the use of deuterium. Amongst the three isotopes of hydrogen, deuterium (2H) has a nucleus composed of one proton and one neutron. When the D2O solvent is added to a pure dry ethanol solution, its labile proton is substituted with deuterium.