Related Experiment Video
Updated: Oct 13, 2026

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
The effect on dose of kilovoltage x-rays backscattered from lead
M S Huq1, N Venkataramanan, J A Meli
1Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT.
Abstract:
Dose enhancement on the backscatter side of a soft tissue/high Z material interface is known to exist for megavoltage x-ray beams. Caused by an increase in backscattered electron fluence, the enhancement persists for short distances upstream of the interface, equal to the range of these electrons. Since photon interaction cross sections are small, there is little photon backscatter at these energies. Consequently, beyond the range of the backscattered electrons, the dose upstream is unaffected by the presence of the interface. A similar dose enhancement has been reported for kilovoltage beams. In this case, due to the very low energy of the backscattered electrons, the enhancement persists for a very short upstream distance. Since photon interaction cross sections at keV energies are relatively large, there is also a substantial backscattered photon fluence. This experimental work investigates the effect of these photons on dose at distances upstream from a water/lead interface beyond the range of the backscattered electrons. Measurements of ionization charge, as a function of interface distance and field size for 60, 100, and 250 kV beams, were made with a parallel plate chamber at a fixed depth. A significant underdose was found upstream of the interface compared to a homogeneous water medium. For example, with the 100 kV beam and a 15 x 15 cm2 field the measured underdose is 23% at 3 mm and 14% at 1.5 cm upstream of the interface. The effect decreases with field size. In fact, for a 2 x 2 cm2 field the upstream dose in unaffected by the interface. Detailed results for this and the other two beams are presented along with backscatter factor measurements for lead. An explanation for the observed underdose is also presented.
Related Concept Videos
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay:
Biological Effects of Radiation
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

