Related Experiment Video
Updated: Aug 19, 2026

Using Gold-standard Gait Analysis Methods to Assess Experience Effects on Lower-limb Mechanics During Moderate High-heeled Jogging and Running
Published on: September 14, 2017
Modifications of the Weil osteotomy have no effect on plantar pressure
Johnny T C Lau1, Emmanouil D Stamatis, Brent G Parks
1Department of Orthopaedic Surgery, The Union Memorial Hospital, Baltimore, MD 21218, USA.
Abstract:
Previous studies have shown that increasing angulation of the Weil osteotomy produces greater plantar translation of the metatarsal head. Modifications have been proposed to reduce plantar translation. However, there is no evidence that the increased plantar translation with a Weil osteotomy is clinically significant or that these modifications are required. Ten lower extremities consisting of five matched pairs were used to evaluate whether different configurations of the Weil osteotomy altered plantar pressure in a dynamic cadaver model. For each pair, an oblique Weil osteotomy with a 5-mm shift was done on one side and a standard (parallel) Weil osteotomy with a 5-mm shift was done on the matched foot. A 4-mm slice resection and a metatarsal head resection then were done sequentially. Plantar pressures were measured with cyclic loading to 700 N at a frequency of 1 Hz with an F-scan in-shoe sensor on the intact specimens and after each intervention. Increased plantar translation of the metatarsal head with a more oblique Weil osteotomy did not significantly increase plantar pressure, and the 4-mm slice resection did not significantly unload the metatarsal head. Only complete metatarsal head resection significantly unloaded the metatarsal head.