Background:
Cerebral hypoxia (cerebral cortical oxygenation [Pbro2] < 20 mm Hg) monitored by direct measurement has been shown in animal and small clinical studies to be associated with poor outcome. We present our preliminary results observing Pbro2 in patients with traumatic brain injury (TBI).
Methods:
A prospective observational cohort study was performed. Institutional review board approval was obtained. All patients with TBI who required measurement of intracranial pressure (ICP), cerebral perfusion pressure (CPP), and Pbro2 because of a Glasgow Coma Scale score < 8 were enrolled. Data sets (ICP, CPP, Pbro2, positive end-expiratory pressure (PEEP), Pao2, and Paco2) were recorded during routine manipulation. Episodes of cerebral hypoxia were compared with episodes without. Results are displayed as mean +/- SEM; t test, chi2, and Fisher's exact test were used to answer questions of interest.
Results:
One hundred eighty-one data sets were abstracted from 20 patients. Thirty-five episodes of regional cerebral hypoxia were identified in 14 patients. Compared with episodes of acceptable cerebral oxygenation, episodes of cerebral hypoxia were noted to be associated with a significantly lower mean Pao2 (144 +/- 14 vs. 165 +/- 8; p < 0.01) and higher mean PEEP (8.8 +/- 0.7 vs. 7.1 +/- 0.3; p < 0.01). Mean ICP and CPP measurements were similar between groups. In a univariate analysis, cerebral hypoxic episodes were associated with Pao2 < or = 100 mm Hg (p < 0.01) and PEEP > 5 cm H2O (p < 0.01), but not ICP > 20 mm Hg, CPP < or = 65 mm Hg, or Pac2 < or = 35 mm Hg.
Conclusion:
Cerebral oxymetry is confirmed safe in the patient with multiple injuries with TBI. Occult cerebral hypoxia is present in the traumatic brain injured patient despite normal traditional measurements of cerebral perfusion. Further research is necessary to determine whether management protocols aimed at the prevention of cerebral cortical hypoxia will affect outcome.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Transport in the Blood
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...