Related Experiment Video
Updated: Aug 17, 2026

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Hemodynamic significance of high brachial pulse pressure in young men
José Alfie1, Claudio Majul, Olga Paez
1Unidad de Hipertensión Arterial, Servicio de Clínica Medica, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina. jose.alfie@hospitalitaliano.org.ar
Abstract:
This study investigates whether an increased brachial pulse pressure (PP) in young healthy men constitutes a representative measure of the central hemodynamic forces, or the mere expression of an exaggerated upper limb amplification. Thirty two healthy men between 17 and 28 years old underwent noninvasive evaluation of systemic hemodynamics (impedance cardiography) and pulse wave analysis (SphygmoCor). Subjects were divided into 3 predefined groups of brachial PP: < 50, 50-64, and > or = 65 mmHg. The brachial-central PP difference increased with increasing brachial PP (17 +/- 4, 22 +/- 4, and 29 +/- 4 mmHg, respectively P < 0.001). In contrast, peripheral amplification (as measured by the brachial:central PP ratio) remained constant among the tree groups, at the expense of a concomitant widening of aortic PP (P < 0.001) without difference in augmentation index. In the entire sample, central and brachial PP, and the difference between the two measures, correlated positively with cardiac output (P < 0.001) and stroke volume (P < 0.01), and negatively with systemic vascular resistance (P < 0.001), without significant relationship with heart rate. In conclusion, despite the different amplitude, central and brachial PP shared common hemodynamic determinants. A high PP among young men underlied a high output-low resistance circulatory pattern, independently of the site of measurement.
More Related Videos
05:51Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Pressure
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...