Related Experiment Video
Updated: Aug 24, 2026

ELIME (Enzyme Linked Immuno Magnetic Electrochemical) Method for Mycotoxin Detection
Published on: October 23, 2009
Monoclonal antibodies and sandwich ELISA for quantitation of HM-1 killer toxin
Tadazumi Komiyama1, Qing-Zhu Zhang, Masahiko Miyamoto
1Department of Biochemistry, Faculty of Pharmaceutical Sciences, Niigata University of Pharmacy and Applied Life Sciences, Japan. tkomiyam@nigata-pharm.ac.jp
To establish a method for quantitative analysis of HM-1 killer toxin (HM-1), two purified mouse monoclonal antibodies, 1F1 and 4A2, and rabbit polyclonal antiserum against HM-1 were prepared. Both monoclonal antibodies were classified as IgG1(kappa) subtype, and did not neutralize the killing activity of HM-1. By SPOTs analysis, the epitope of 1F1 was found in the sequence of CDPNTG with a corresponding sequence of 11-16 from N-terminal amino acid residues of HM-1, but the epitope of 4A2 was not determined. Using 4A2 and polyclonal antiserum, the sandwich enzyme-linked immunosorbent assay (ELISA) was applied to establish the quantitative determination of HM-1. The concentration of HM-1 was determined successfully at the range of 2.5-100 ng/ml. But in the case of 1F1, the method was not established. Genes were constructed to apply the system to the measurement of the secreted concentrations of mutant HM-1, and it was evident that the production of mutant toxins varied among HM-1 mutant genes. The findings of this study are unique in determinimg the epitope of monoclonal antibody against HM-1, and in quantifying the HM-1 using the spot analysis and sandwich ELISA methods.
To establish a method for quantitative analysis of HM-1 killer toxin (HM-1), two purified mouse monoclonal antibodies, 1F1 and 4A2, and rabbit polyclonal antiserum against HM-1 were prepared. Both monoclonal antibodies were classified as IgG1(kappa) subtype, and did not neutralize the killing activity of HM-1. By SPOTs analysis, the epitope of 1F1 was found in the sequence of CDPNTG with a corresponding sequence of 11-16 from N-terminal amino acid residues of HM-1, but the epitope of 4A2 was not determined. Using 4A2 and polyclonal antiserum, the sandwich enzyme-linked immunosorbent assay (ELISA) was applied to establish the quantitative determination of HM-1. The concentration of HM-1 was determined successfully at the range of 2.5-100 ng/ml. But in the case of 1F1, the method was not established. Genes were constructed to apply the system to the measurement of the secreted concentrations of mutant HM-1, and it was evident that the production of mutant toxins varied among HM-1 mutant genes. The findings of this study are unique in determinimg the epitope of monoclonal antibody against HM-1, and in quantifying the HM-1 using the spot analysis and sandwich ELISA methods.
More Related Videos
08:28Validated Immunochemical Assay for Comprehensive Determination of the Human Epidermal Growth Factor Receptor 2 Released from and Bound to Cells
Published on: May 9, 2025
08:40An ELISA Based Binding and Competition Method to Rapidly Determine Ligand-receptor Interactions
Published on: March 14, 2016
Related Concept Videos
Hybridoma Technology
Hybridoma Selection
Commonly used fusion techniques — electroporation, polyethylene glycol...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.