Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform
Sarah A Hope1, Ian T Meredith, James D Cameron
1Cardiovascular Research Centre, Monash University, Monash Medical Centre, 246 Clayton Road, Clayton, Victoria 3168, Australia.
Abstract:
Transfer function techniques are increasingly used for non-invasive estimation of central aortic waveform characteristics. Non-invasive radial waveforms must be calibrated for this purpose. Most validation studies have used invasive pressures for calibration, with little data on the impact of non-invasive calibration on transfer-function-derived aortic waveform characteristics. In the present study, simultaneous invasive central aortic (Millar Mikro-tip catheter transducer) and non-invasive radial (Millar Mikro-tip tonometer) pressure waveforms and non-invasive brachial pressures (Dinamap) were measured in 42 subjects. In this cohort, radial waveforms were calibrated to both invasive and non-invasive mean and diastolic pressures. From each of these, central waveforms were reconstructed using a generalized transfer function obtained by us from a previous cohort [Hope, Tay, Meredith and Cameron (2002) Am. J. Physiol. Heart Circ. Physiol. 283, H1150-H1156]. Waveforms were analysed for parameters of potential clinical interest. For calibrated radial and reconstructed central waveforms, different methods of calibration were associated with differences in pressure (P<0.001), but not time parameters or augmentation index. Whereas invasive calibration resulted in little error in transfer function estimation of central systolic pressure (difference -1+/-8 mmHg; P=not significant), non-invasive calibration resulted in significant underestimation (7+/-12 mmHg; P<0.001). Errors in estimated aortic parameters differed with non-invasively calibrated untransformed radial and transfer-function-derived aortic waveforms (all P<0.01), with smaller absolute errors with untransformed radial waveforms for most pressure parameters [systolic pressure, 5+/-16 and 7+/-12 mmHg; pulse pressure, 0+/-16 and 4+/-12 mmHg (radial and derived aortic respectively)]. When only non-invasive pressures are accessible, analysis of untransformed radial waveforms apparently produces smaller errors in the estimation of central aortic systolic pressure, and other waveform parameters, than using a generalized transfer function.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.