Related Experiment Video
Updated: Aug 24, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
The effect of opening windows on air change rates in two homes
Cynthia Howard-Reed1, Lance A Wallace, Wayne R Ott
1National Exposure Research Laboratory, U.S. Environmental Protection Agency, Reston, Virginia, USA. chreed@nist.gov
Abstract:
More than 300 air change rate experiments were completed in two occupied residences: a two-story detached house in Redwood City, CA, and a three-story townhouse in Reston, VA. A continuous monitor was used to measure the decay of SF6 tracer gas over periods of 1-18 hr. Each experiment first included a measurement of the air change rate with all exterior doors and windows closed (State 0), then a measurement with the single change from State 0 conditions of opening one or more windows. The overall average State 0 air change rate was 0.37 air changes per hour (hr(-1)) (SD = 0.10 hr(-1); n = 112) for the California house and 0.41 hr(-1) (SD = 0.19 hr(-1); n = 203) for the Virginia house. Indoor/outdoor temperature differences appeared to be responsible for the variation at the Virginia house of 0.15-0.85 hr(-1) when windows were closed. Opening a single window increased the State 0 air change rate by an amount roughly proportional to the width of the opening, reaching increments as high as 0.80 hr(-1) in the California house and 1.3 hr(-1) in the Virginia house. Multiple window openings increased the air change rate by amounts ranging from 0.10 to 2.8 hr(-1) in the California house and from 0.49 to 1.7 hr(-1) in the Virginia house. Compared with temperature differences and wind effects, opening windows produced the greatest increase in the air change rates measured in both homes. Results of this study indicate the importance of occupant window-opening behavior on a home's air change rate and the consequent need to incorporate this factor when estimating human exposure to indoor air pollutants.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Two-Way ANOVA
The two-way ANOVA analysis initially begins by stating the null hypothesis that there is an interaction effect between the two factors of a dataset. This effect can be visualized using line segments formed by joining the means for...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
External and Internal Respiration