Related Experiment Video
Updated: Jan 21, 2026

A Novel Surgical Technique in a Sheep Model for Suburethral Graft Implantation
Published on: June 20, 2025
Safety of continuous intrathecal midazolam infusion in the sheep model
Mary J Johansen1, Tamara Lee Gradert, William C Satterfield
1Departments of *Experimental Therapeutics, †Neurosurgery, and ‡Veterinary Sciences and ‖Division of Pharmacy, The University of Texas M. D. Anderson Cancer Center, Houston, Texas; and §Medtronic, Inc., Minneapolis, Minnesota.
Unlabelled:
We investigated the safety of midazolam administered by continuous intrathecal infusion in relevant animal models. Preservative-free midazolam was delivered to sheep and pigs by using implanted infusion systems (SynchroMed pumps plus silicone catheters). Sheep received midazolam 5 mg/d (n = 4) or 15 mg/d (n = 7) or saline (n = 2) for 43 days at 125 micro L/h. One sheep received 10 mg/d. Infusion concentrations ranged from 1.7 to 2.5 mg/mL (5 mg/d) and from 2.5 to 5.0 mg/mL (15 mg/d). Pigs were evaluated for toxicity only and received 15 mg/d (n = 2) or saline (n = 1) for 43 days at 125 micro L/h. Behavior, neurologic function, and vital signs were documented. Serum and cerebrospinal fluid chemistry and cytology were evaluated, and histology was performed on spinal cord tissue. Behavior and neurologic function remained normal in all subjects. Gross and microscopic evaluation of spinal tissue revealed mild inflammation surrounding the catheter tract in both the midazolam-treated and the saline-treated groups. This inflammation was likely attributable to the mechanical presence of the catheter. These data demonstrate that continuous intrathecal infusion of preservative-free midazolam at doses up to 15 mg/d were well tolerated.
Implications:
We investigated the toxicity of preservative-free intrathecal midazolam delivered continuously via implanted infusion systems in sheep and pigs. Doses of 5-15 mg/d were well tolerated. The lack of neurotoxicity observed suggests that intrathecal midazolam may be an alternative for the treatment of intractable pain that is unresponsive to opioids.
Related Concept Videos
Survey Safety
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Cloning of Dolly the Sheep
Household Wiring And Electrical Safety
Continuing Care

