Colour and power Doppler sonography in symptomatic Achilles tendon disease
M Reiter1, N Ulreich, A Dirisamer
1Zentralröntgeninstitut der Krankenanstalt Rudolfstiftung, Vienna, Austria. markus.reiter@akh-wien.ac.at
Abstract:
The present trial focused on the exact role of colour and power Doppler sonography in Achilles tendinopathy and correlated these techniques with the clinical severity of the disease and with findings on grey-scale sonography. Twenty patients with in total 28 symptomatic Achilles tendons were included in this prospective trial. Additionally included were the asymptomatic tendons (n = 12) of patients and both tendons (n = 30) of fifteen controls. The pain score of Robinson - which ranges from 0 (strong severe pain) to 100 (asymptomatic) - was used to assess clinical severity of the disease. Both tendons of patients and controls were examined by a GE LOGIQ 9 trade mark scanner with a small-parts 14 MHz transducer. Grey-scale sonography detected in total 31 focal hypoechoic areas in 19 (68 %) of the 28 symptomatic tendons. Colour as well as power Doppler sonography detected blood flow in 14 (74 %) of the 19 tendons with focal hypoechoic areas. No blood flow was detected in the remaining symptomatic tendons (n = 14) and in the asymptomatic tendons of patients or in both tendons of controls. Colour and power Doppler sonography resulted in a specificity of 100 % and a sensitivity of 50 % for symptomatic Achilles tendinopathy. Patients with blood flow within the tendon had a significantly lower score according to Robinson than symptomatic patients without flow (P = 0.009). It is concluded that colour and/or power Doppler sonography are useful as an adjunct to grey-scale sonography in the examination of Achilles tendinosis, especially because the presence of blood flow is associated with stronger pain, discomfort and physical restriction.
More Related Videos
08:11Ultrasound Tissue Characterization of Human Achilles Tendon by Stability Quantification of Echo Patterns
Published on: September 5, 2025
07:51Reliability of A Vibration-Based Elastography Protocol For Assessing Achilles Tendon Stiffness Across Multiple Joint Angles In Elite Athletes
Published on: June 16, 2026
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: