Related Experiment Video
Updated: Aug 24, 2026

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated
Kyongtae T Bae1, Huy Q Tran, Jay P Heiken
1Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, Box 8131, St Louis, MO 63110, USA. baet@mir.wustl.edu
Purpose:
To investigate in computed tomographic (CT) angiography whether an exponentially decelerated contrast medium injection, as compared with a standard constant-rate injection, can facilitate uniform vascular contrast enhancement with a reduced contrast material volume.
Materials And Methods:
CT angiography of the abdominal aorta was performed in 46 subjects by using an exponentially decelerated injection method: 134 mL of contrast medium was injected for 40 seconds, starting at 4.0 mL/sec and decreasing exponentially to 2.7 mL/sec by the end of the injection. Twenty-one of these subjects also underwent CT angiography with a constant-rate injection: 160 mL of contrast medium was injected for 40 seconds at a constant rate of 4 mL/sec. Time-enhancement curves and the magnitude of peak vascular enhancement were measured. Enhancement uniformity was evaluated by using three indexes: (a) duration of contrast enhancement achieved within 80% of the peak (80% DCE), (b) SD of the normalized contrast enhancement (SDNCE) measured from the beginning of spiral CT scanning to the time when the enhancement decreased to a level lower than the beginning level, and (c) slope of the enhancement curve calculated by using linear regression analysis.
Results:
Exponentially decelerated injection resulted in more uniform enhancement. Mean values generated by using exponentially decelerated versus constant-rate injection in 21 paired comparisons were, respectively, 30.8 seconds +/- 5.0 versus 22.6 seconds +/- 7.6 for 80% DCE, 0.052 +/- 0.017 versus 0.086 +/- 0.031 for SDNCE, and 0.47 HU/sec +/- 0.70 versus 2.27 HU/sec +/- 0.87 for slope (P <.001 for all indexes). Compared with the peak enhancement resulting from the constant-rate injection, that resulting from the exponentially decelerated injection was reduced by a mean of 17.2% +/- 10.0.
Conclusion:
Uniform vascular contrast enhancement and reduced contrast medium volume, which are desirable in CT angiography, can be achieved with exponentially decelerated injection.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
05:26Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...