Related Experiment Video
Updated: Aug 24, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Mouth closing device (chinstrap) reduces mouth leak during nasal CPAP
Adel Bachour1, Kirsti Hurmerinta, Paula Maasilta
1Department of Pulmonary Medicine, Helsinki University Central Hospital, P.O. Box 340, Hus FIN 00029, Finland. adel.bachour@hus.fi
Background And Purpose:
Mouth leak occasionally complicates continuous positive airway pressure (CPAP) therapy, which leads to discomfort. While a chinstrap prevents the mouth from opening during sleep, its efficacy in diminishing mouth leak has not been studied.
Patients And Methods:
Fifteen patients with mouth leak complaining of mouth dryness and nasal obstruction underwent two consecutive overnight polysomnographies, one with a chinstrap, in random order. Cephalometry with and without a chinstrap was randomly performed on six patients.
Results:
With the chinstrap, both mouth leak and the arousal index decreased significantly, from (mean+/-SD) 42.9+/-23.5 to 23.8+/-13.3% of total sleep time (TST), and from 33.4+/-18.6 to 23.6+/-9.3/sleep hour, respectively. However, snoring time showed a concomitant increase from 6.7+/-14.3 to 24.0+/-13.2% of TST. The arousal index was significantly higher during leak periods, and its changes correlated positively with changes in mouth leak. Cephalometric measures showed a significant decrease in anterior lower facial height.
Conclusions:
The chinstrap, by closing the mouth during CPAP, reduces mouth leak and therefore the arousal index in most patients. Nevertheless, the indices remained unacceptably high. The chinstrap may also increase snoring and, in rare cases, can worsen the respiratory disturbance index. Consideration of these potential effects is important before instituting regular home use of the chinstrap.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Sleep Apnea
The condition is more prevalent among...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...