Related Experiment Video
Updated: Aug 24, 2026

Quantification of Vascular Parameters in Whole Mount Retinas of Mice with Non-Proliferative and Proliferative Retinopathies
Published on: March 12, 2022
Quantitative assessment of the morphology of renal arteries from X-ray images: quantitative vascular analysis
Hans C van Assen1, G Boudewijn C Vasbinder, Berend C Stoel
1Division for Image Processing, Department of Radiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, the Netherlands.
Rationale And Objectives:
With the advent of interventional vascular procedures, objective and reproducible tools are needed to assist clinical decision-making and to assess intervention efficacy. The success of quantitative coronary arteriography (QVA) in objectively assessing cardiovascular morphology has initiated the software development for quantitative analysis of peripheral vasculature. The objective of this study was to evaluate the applicability and quality of a new QVA package applied to renal arteries.
Methods:
A calibration method was developed using markers mounted on a catheter's shaft, ensuring accurate calibration even with small catheter sizes. Given the high prevalence of ostial stenoses in peripheral vessels, a dedicated vessel analysis method was developed to assess these stenoses. Its reproducibility was determined in renal angiography. Variance component analysis was performed to evaluate sources of variability, using angiograms from 74 patients suspected of renovascular hypertension.
Results:
For intraobserver variability, the 95% confidence intervals of differences in percent diameter stenosis and minimal lumen diameter were -1.99%-1.04% (P = 0.53, n = 48) and -0.081 mm-0.023 mm (P = 0.27, n = 48), respectively. For the interobserver variability, intervals were -1.86%-2.80% (P = 0.69, n = 66) and -0.46 mm-0.053 mm (P = 0.12, n = 46), respectively.
Conclusions:
The contribution of intraobserver variation was negligible. The contribution of interobserver variation for different parameters was negligible or comparable with the variation caused by image acquisition. These conclusions demonstrate that QVA can reproducibly measure renal artery geometry.
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...