Related Experiment Video
Updated: Aug 9, 2026

Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules
Published on: May 23, 2015
The performance of( 18)F-fluorodeoxyglucose positron emission tomography in small solitary pulmonary nodules
Gerarda J Herder1, Richard P Golding, Otto S Hoekstra
1Department of Pulmonary Diseases, VU University Medical Centre, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands.
Abstract:
Solitary pulmonary nodule (SPN, intraparenchymal lung mass <3 cm) is often a diagnostic challenge. This study was performed to evaluate the diagnostic accuracy of( 18)F-fluorodeoxyglucose positron emission tomography (FDG PET) in radiologically indeterminate SPN < or =10 mm on spiral CT. Between August 1997 and March 2001, we identified all patients with radiologically indeterminate SPNs < or =10 mm who were referred for FDG PET imaging at the VU University Medical Centre. All PET scans were retrospectively reviewed by an experienced nuclear medicine physician. PET was considered positive in cases with at least moderately enhanced focal uptake, and otherwise as negative. Lesions were considered benign on the basis of histology, no growth during 1.5 years or disappearance within at least 6 months. Thirty-five patients with 36 SPNs < or =10 mm in diameter at clinical presentation were identified (one patient had two metachronous lesions). In 13 of 14 malignant nodules and in two of 22 benign nodules, diagnosis was confirmed by histology. Prevalence of malignancy was 39%. PET imaging correctly identified 30 of 36 small lesions. One lesion proved to be false negative on PET (CT: 10 mm), and in five lesions, PET scans proved to be false positive. Specificity was 77% (17/22; 95% CI: 0.55-0.92), sensitivity 93% (13/14; 95% CI: 0.66-1.0), positive predictive value 72% (13/18; 95% CI: 0.46-0.90) and negative predictive value 94% (17/18; 95% CI: 0.73-1.0). This retrospective study suggests that FDG PET imaging could be a useful tool in differentiating benign from malignant SPNs < or =10 mm in diameter at clinical presentation. Such results may help in the design of larger prospective trials with structured clinical work-up.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

