Related Experiment Video
Updated: Aug 9, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Noninvasive evaluation of cardiac output during postural change and exercise in humans: comparison between the
K Matsukawa1, T Kobayashi, T Nakamoto
1Department of Physiology, Graduate School of Health Sciences, Hiroshima University, Hiroshima, 734-8551 Japan. matsuk@hiroshima-u.ac.jp
Abstract:
To investigate whether the Model-flow method, by simulating the aortic input impedance model from a noninvasive monitoring of arterial blood pressure, reflected a reliable measure of cardiac output (CO) during postural change and whole-body exercise occurring in daily life, we compared the Modelflow-estimated CO with a simultaneous reference determined by the pulse dye-densitometry. Nine healthy volunteers performed postural change from supine to upright and dynamic stepping exercise. The Modelflow-estimated CO decreased to 4.8 +/- 0.5 l/min, from 5.8 +/- 0.6 l/min, during the postural change and increased to 12.8 +/- 1.3 l/min during a stepping exercise, returning to 5.1 +/- 0.4 l/min at 5 min after exercise. When comparing the pooled data of CO during resting and following exercise between the Modelflow and pulse dye-densitometry, we found that the average CO did not differ between the two estimates and that there was a significant correlation between them; the slope of the linear regression line corresponded to approximately 1.0. Although such linear relationship was also observed in an individual subject, the slope of the regression line varied from 0.737 to 1.588 among the subjects. The calibration of the Modelflow-estimated CO with the dye-densitometry value at supine or upright improved a correlation between the two estimates. Thus it is likely that the noninvasive Modelflow simulation from arterial blood pressure can provide a reliable estimation of group-average cardiac output during postural change and stepping exercise occurring in daily life. It will be recommended for a more accurate estimation of cardiac output in a given subject to calibrate the Modelflow data with an independent measure.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

