Optimized dynamic rotation with wedges.

I I Rosen1, S M Morrill, R G Lane

  • 1Department of Radiation Therapy, University of Texas Medical Branch, Galveston 77550.

Medical Physics
|July 1, 1992
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Wave-front reconstruction using a Shack-Hartmann sensor.

Applied optics·2010
Same author

Phase retrieval with prior information.

Journal of the Optical Society of America. A, Optics and image science·2008
Same author

Modeling scintillation from an aperiodic Kolmogorov phase screen.

Applied optics·2008
Same author

Analysis of optimal centroid estimation applied to Shack-Hartmann sensing.

Applied optics·2008
Same author

Fast simulation of a kolmogorov phase screen.

Applied optics·2008
Same author

MLC dosimetric characteristics for small field and IMRT applications.

Medical physics·2003
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

Optimized dynamic rotation radiotherapy, varying dose rate with gantry angle, improved treatment plans compared to simple dynamic rotation. Wedges did not offer significant additional benefits in this study.

Area of Science:

  • Radiation Oncology
  • Medical Physics

Background:

  • Dynamic rotation is a computer-controlled radiotherapy technique.
  • It uses an automated multileaf collimator to dynamically adjust the radiation beam shape.
  • This ensures the beam matches the target volume's projected shape during machine rotation.

Purpose of the Study:

  • To compare simple and optimized dynamic rotation treatment plans for a pancreatic tumor.
  • To evaluate the impact of wedges on treatment plan quality.
  • To assess the effectiveness of varying dose rate as a function of gantry angle.

Main Methods:

  • Optimized dynamic rotation involved varying dose rate based on gantry angle, computed via linear programming.
  • Treatment plans were created with and without wedges.

Related Experiment Videos

  • Continuous rotation was approximated by static beams at discrete gantry angles.
  • Plan quality was assessed using cost function values, normal tissue complication probabilities, and positive difference statistics.
  • Main Results:

    • Optimized dynamic rotation (both open and wedged) outperformed simple dynamic rotation.
    • No significant improvement in treatment plan quality was observed with more than 36 beam angles.
    • Wedged optimized dynamic rotation did not show a definitive advantage over open beam optimized dynamic rotation.

    Conclusions:

    • Optimized dynamic rotation offers superior treatment planning compared to simple dynamic rotation.
    • Increasing beam angles beyond 36 provided diminishing returns for plan optimization.
    • The addition of wedges did not yield significant improvements in the studied pancreatic tumor case.