Related Experiment Videos
Outpatient treatment of spontaneous pneumothorax using an improved pocket sized Heimlich valve
K Y Chan1, M Fikri-Abdullah, M Sajjad
1Division of Cardiothoracic Surgery, Department of Surgery, Hospital Universiti Kebangsaan Malaysia, Cheras, 56000, Kuala Lumpur.
Abstract:
We report two patients, who have used Pneumostat to replace the conventional underwater seal drainage system for recurrent pneumothorax. Both patients had required repeated chest tube insertion for recurrent pneumothorax and needed a longer hospital stay. Both patients were able to be discharged with the Pneumostat device and were reviewed in outpatient clinic. Both patients had optimal clinical improvement and chest X-ray showed no residual pneumothorax.
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Pneumothorax-I
Pneumothorax can be even further classified as spontaneous, traumatic, and tension pneumothorax.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...