Characteristics of virtual unipolar electrograms for detecting isthmus block during radiofrequency ablation of
Yenn-Jiang Lin1, Ching-Tai Tai, Jin-Long Huang
1Division of Cardiology, Department of Medicine, National Yang-Ming University School of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.
Objectives:
The purpose of this study was to investigate the characteristics of the second component of local virtual unipolar electrograms recorded at the ablation line during coronary sinus (CS) pacing after radiofrequency ablation (RFA) of the cavotricuspid isthmus (CTI) for typical atrial flutter (AFL).
Background:
Radiofrequency ablation of the CTI can produce local double potentials at the ablation line. The second component of unipolar electrograms represents the approaching wavefront in the right atrium opposite the pacing site. We hypothesized that the morphologic characteristics of the second component of double potentials would be useful in detecting complete CTI block.
Methods:
Radiofrequency ablation of the CTI was performed in 52 patients (males = 37, females = 15, 62 +/- 12 years) with typical AFL. The noncontact mapping system (Ensite 3000, Endocardial Solutions, St. Paul, Minnesota) was used to guide RFA. Virtual unipolar electrograms along the ablation line during CS pacing after RFA were analyzed. Complete or incomplete CTI block was confirmed by the activation sequence on the halo catheter and noncontact mapping.
Results:
Three groups were classified after ablation. Group I (n = 37) had complete bidirectional CTI block. During CS pacing, the second component of unipolar electrograms showed an R or Rs pattern. Group II (n = 12) had incomplete CTI block. The second component of unipolar electrograms showed an rS pattern. Group III (n = 3) had complete CTI block with transcristal conduction. The second component of unipolar electrograms showed an rSR pattern.
Conclusions:
A predominant R-wave pattern in the second component of unipolar double potentials at the ablation line indicates complete CTI block, even in the presence of transcristal conduction.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Electrophysiology of Normal Cardiac Rhythm