Related Experiment Video
Updated: Aug 23, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
The predictive characteristics of D-dimer testing in outpatients with suspected venous thromboembolism: a Bayesian
Lorenz Risch1, Antoinette Monn, Regina Lüthy
1Clinical Decision Making Research Unit, Vorarlberg Institute for Vascular Investigation and Treatment, Feldkirch, Austria.
Background:
Despite the widespread use of quantitative methods to measure D-dimer, clinical decisions commonly are based only on binary test information (positive/negative). This study aimed to determine the significance of quantitative D-dimer results in the evaluation of venous thromboembolism (VTE) by means of a differentiated Bayesian approach.
Methods:
Prospective study in 118 outpatients referred for workup of suspected pulmonary embolism (n = 75) or deep vein thrombosis (n = 43). The sensitivity and specificity of D-dimer results obtained by DD VIDAS (Biomerieux, France), STA Liatest (Diagnostica Stago, France), and D-dimer plus (Dade, US) were assessed for five different cut-offs. Further, predictive values and multilevel likelihood ratios were calculated in order to assess the operative test characteristics in excluding or confirming VTE.
Results:
At a cut-off of 500 ng/ml and pretest probabilities < 47%, the VIDAS provides a negative predictive value (NPV) > 95%, whereas a positive predictive value (PPV) > 95% is obtained in patients with a D-dimer > 10,000 ng/ml and pretest probabilities > 50%. At a cut-off of 500 ng/ml and pretest probabilities < 33%, the Liatest exhibits a NPV > 95%, whereas a PPV > 95% is obtained in patients with a D-dimer >10,000 ng/ml and pretest probabilities > 37%. Finally, with the D-dimer plus, a NPV > 95% is seen at a cut-off of 150 ng/ml and pretest probabilities < 30%, whereas a PPV > 95% is obtained at a cut-off > 1000 ng/ml and pretest probabilities > 67%.
Conclusions:
D-dimer measurements in outpatients cannot only allow for exclusion but, in some situations, also for confirmation of venous thromboembolism. It is therefore advisable to conduct a quantitative interpretation of D-dimer results.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis I: Introduction
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...