Related Experiment Video
Updated: Aug 23, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
Validation of the portable VmaxST system for oxygen-uptake measurement
M-A Brehm1, J Harlaar, H Groepenhof
1Department of Rehabilitation Medicine, University Hospital 'Vrije Universiteit', P.O. Box 7057, 1007 MB Amsterdam, The Netherlands. m.brehm@vumc.nl
Abstract:
The aim of this study was to validate the accuracy of a new type of portable gas-analysis system (Sensormedics VmaxST) for the measurement of oxygen-uptake at expenditure levels that are reached during walking in patients with movement disorders. The criterion method was the Douglas Bag (DB) method, which is considered to be the gold standard. Accuracy evaluations were made in two trials, randomly using the VmaxST (ST) and the Douglas Bag method. Ten healthy adult subjects participated in the trials (age: 28.8 (4.3) years; body mass: 75 (13.3)kg; height: 179.3 (8.9)cm). Each trial consisted of two time periods: 5 min of resting in a comfortable chair and 5 min of cycling at an 80 W workload. During the fifth minute of each block, mean minute ventilation (VE), oxygen-uptake (VO2), and carbon dioxide production (VCO2) were measured or calculated for both systems. Energy expenditure (EE) values were calculated and net values calculated by subtracting resting measurements from gross measurements. The results show that no significant differences were found between the VmaxST and the Douglas Bag method for the primary parameters: EEnet and VO2net. Significantly higher values were found for rest and exercise values. However, these differences were very small. Therefore, the validity of the VmaxST is sufficient for use in gait studies to determine the energy cost of walking, especially when net values are calculated.
More Related Videos
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...